The smart Trick of British Pendulum Skid Resistance Tester That Nobody is Discussing
The smart Trick of British Pendulum Skid Resistance Tester That Nobody is Discussing
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it concerns guaranteeing security in commercial, industrial, and property spaces, slip resistance testing is an important element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and homeowner alleviate risks and abide by security standards.
With advanced devices such as the pendulum slip test maker and moisture meter for concrete, we provide accurate and independent slip testing services throughout Australia. Our expertise covers ASTM F2170 compliance, R Rating assessments, P Score tiles, and more, guaranteeing your floorings meet the highest security standards.
Why Slip Resistance Testing is Essential
Slips and falls are among the leading reasons for workplace and public injuries. Proper slip testing assists recognize harmful surface areas before accidents occur. Whether you need wet pendulum test examinations or pendulum test for slip resistance, ATTAR provides exact outcomes to boost safety.
Key Services Offered by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Ranking and P Score tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Guarantees presence for visually impaired people.
- Complies with Australian accessibility standards.
4. On-Site & Lab Testing
- Slip test machine for accurate on-site evaluations.
- Wet pendulum test for wet surface slip resistance.
Understanding Slip Resistance Ratings: R Rating vs. P Rating
When carrying out slip resistance testing, 2 essential categories are utilized:.
- R Ranking (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, commonly utilized in Europe.
- P Rating (Pendulum Test - AS 4586)
Evaluates dynamic friction utilizing a pendulum test slip resistance device, commonly adopted in Australia.
ATTAR offers independent slip testing to figure out whether your floor covering satisfies the required pendulum rating tiles standards.
The Importance of Concrete Moisture Testing
Excess moisture in concrete slabs can lead to floor covering failures, mold development, and adhesive degradation. Our concrete moisture testing services include:.
> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to guarantee ideal conditions for floor installations.
By discovering moisture issues early, we help prevent pricey repairs and ensure lasting floor covering performance.
Luminance Contrast for Availability Compliance
Correct luminance contrast is important for visually impaired individuals to browse areas securely. ATTAR assesses:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.
Our evaluations guarantee compliance with Australian Impairment Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where relevant).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Quick & Trusted Reporting.
For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Common Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping center, restaurants, and offices need safe flooring to prevent consumer and employee injuries. Our pendulum slip test ensures compliance with security policies.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments require resilient, slip-resistant flooring. ATTAR's slip testing services assist maintain office safety.
3. Health Care & Aged Care Facilities
Healthcare facilities and nursing homes need to lessen slip risks. Our luminance contrast and slip resistance testing guarantee safe mobility for clients and staff.
4. Public Facilities
Footpaths, train stations, and federal government structures require independent slip testing to fulfill accessibility and security requirements.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Assessment
We assess flooring products and conditions (dry, damp, or polluted).
Action 2: Pendulum Slip Test (AS 4663)
Using a slip test device, we determine the dynamic coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Imitates slippery conditions to evaluate real-world slip threats.
Step 4: Reporting & Compliance Certification
In-depth reports with R Rating or P Score tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance technique includes a swinging arm with a rubber slider that imitates a foot's motion. The test measures:.
- Slip Possible Value (SPV).
- Pendulum score tiles category (P0 to P5).
Greater ratings (P4/P5) suggest much better slip resistance.
Moisture Testing for Concrete Floors: Avoiding Failures
Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture more info test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted service provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and compliant testing services.
Ensure your residential or commercial property fulfills security requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By choosing ATTAR, you purchase independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security options. Let us assist you create safer, compliant, and moisture-resistant environments. Report this page